{"product_id":"water-chiller","title":"Water Chillers","description":"\u003c!-- ===================== INDUSTRIAL FIBER LASER WATER CHILLER ===================== --\u003e\n\u003cdiv style=\"font-family: Arial, Helvetica, sans-serif; color: #222; line-height: 1.6; margin: 35px 0;\"\u003e\n\u003c!-- SECTION HEADER --\u003e\n\u003cdiv style=\"border-bottom: 3px solid #17384f; padding-bottom: 12px; margin-bottom: 28px;\"\u003e\n\u003ch2 style=\"margin: 0; color: #222; font-size: 28px;\"\u003eIndustrial Fiber Laser Water Chiller\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003c!-- INTRODUCTION --\u003e\n\u003cp style=\"margin: 0 0 18px;\"\u003eThe \u003cstrong\u003eTommy Industrial fiber laser water chiller\u003c\/strong\u003e is engineered to provide stable and efficient temperature control for demanding laser-cutting applications. Proper cooling helps protect the laser source and optical components while supporting consistent cutting performance during extended production cycles.\u003c\/p\u003e\n\u003cp style=\"margin: 0 0 28px;\"\u003eDesigned for compatibility with multiple fiber laser brands, the chiller combines precise temperature regulation, dependable alarm protection, low failure rates, and energy-efficient operation. Environmentally responsible refrigerant configurations are available to support installation requirements in markets worldwide.\u003c\/p\u003e\n\u003c!-- FEATURE CARDS --\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 16px; margin-bottom: 32px;\"\u003e\n\u003cdiv style=\"flex: 1 1 220px; background: #f7f7f7; border: 1px solid #ddd; border-radius: 8px; padding: 20px;\"\u003e\n\u003ch3 style=\"margin: 0 0 8px; color: #17384f; font-size: 18px;\"\u003ePrecision Temperature Control\u003c\/h3\u003e\n\u003cp style=\"margin: 0;\"\u003eTemperature-control accuracy of up to \u003cstrong\u003e±0.1°C\u003c\/strong\u003e helps maintain stable operating conditions for the laser source and cutting system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 220px; background: #f7f7f7; border: 1px solid #ddd; border-radius: 8px; padding: 20px;\"\u003e\n\u003ch3 style=\"margin: 0 0 8px; color: #17384f; font-size: 18px;\"\u003eDual-Circuit Cooling\u003c\/h3\u003e\n\u003cp style=\"margin: 0;\"\u003eSeparate normal-temperature and chilled-water settings provide controlled cooling for different components within the fiber laser system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 220px; background: #f7f7f7; border: 1px solid #ddd; border-radius: 8px; padding: 20px;\"\u003e\n\u003ch3 style=\"margin: 0 0 8px; color: #17384f; font-size: 18px;\"\u003eIntegrated Protection\u003c\/h3\u003e\n\u003cp style=\"margin: 0;\"\u003eStandard water-flow and water-pressure alarms help identify cooling-system problems before they can affect machine operation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- PERFORMANCE HIGHLIGHT --\u003e\n\u003cdiv style=\"background: #17384f; color: #fff; border-radius: 8px; padding: 24px; margin-bottom: 32px;\"\u003e\n\u003ch3 style=\"margin: 0 0 10px; color: #fff; font-size: 22px;\"\u003e\u003cspan style=\"color: rgb(255, 255, 255);\"\u003eStable Cooling for Consistent Laser Performance\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp style=\"margin: 0;\"\u003e\u003cspan style=\"color: rgb(255, 255, 255);\"\u003eMaintaining the proper operating temperature is essential for reliable fiber laser performance. The industrial water chiller continuously circulates controlled cooling water to help prevent overheating, reduce thermal variation, and support consistent beam quality throughout the cutting process.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- TECHNICAL SPECIFICATIONS --\u003e\n\u003ch3 style=\"margin: 0 0 15px; color: #17384f; font-size: 22px;\"\u003eWater Chiller Specifications\u003c\/h3\u003e\n\u003cdiv style=\"width: 100%; overflow-x: auto; margin-bottom: 30px;\"\u003e\n\u003ctable style=\"width: 100%; min-width: 600px; border-collapse: collapse; font-family: Arial, Helvetica, sans-serif;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #222; color: #fff;\"\u003e\n\u003cth style=\"padding: 12px; border: 1px solid #ccc; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"padding: 12px; border: 1px solid #ccc; text-align: left;\"\u003eStandard Configuration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #ccc; font-weight: bold;\"\u003eEquipment Type\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #ccc;\"\u003eIndustrial Fiber Laser Water Chiller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #ccc; font-weight: bold;\"\u003eInput Power\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #ccc;\"\u003e380V \/ 50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #ccc; font-weight: bold;\"\u003eCooling Medium\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #ccc;\"\u003eDistilled Water or Deionized Water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #ccc; font-weight: bold;\"\u003eTemperature-Control Accuracy\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #ccc;\"\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #ccc; font-weight: bold;\"\u003eNormal-Temperature Water Setting\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #ccc;\"\u003e30°C Standard, Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #ccc; font-weight: bold;\"\u003eChilled-Water Setting\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #ccc;\"\u003e25°C Standard, Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #ccc; font-weight: bold;\"\u003eMaximum Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #ccc;\"\u003e40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #ccc; font-weight: bold;\"\u003eMinimum Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #ccc;\"\u003e10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f7f7f7;\"\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #ccc; font-weight: bold;\"\u003eWater-Flow Alarm\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #ccc;\"\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #ccc; font-weight: bold;\"\u003eWater-Pressure Alarm\u003c\/td\u003e\n\u003ctd style=\"padding: 11px; border: 1px solid #ccc;\"\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c!-- BENEFITS --\u003e\n\u003ch3 style=\"margin: 0 0 15px; color: #17384f; font-size: 22px;\"\u003eKey Benefits\u003c\/h3\u003e\n\u003cul style=\"margin: 0; padding-left: 22px; line-height: 1.9;\"\u003e\n\u003cli\u003eDesigned specifically for industrial fiber laser equipment\u003c\/li\u003e\n\u003cli\u003eCompatible with multiple fiber laser source brands\u003c\/li\u003e\n\u003cli\u003eHelps protect the laser source and optical components from overheating\u003c\/li\u003e\n\u003cli\u003eMaintains consistent cooling during extended production cycles\u003c\/li\u003e\n\u003cli\u003eHigh-accuracy temperature regulation for stable machine performance\u003c\/li\u003e\n\u003cli\u003eStandard water-flow and water-pressure monitoring\u003c\/li\u003e\n\u003cli\u003eLow failure rate and dependable industrial operation\u003c\/li\u003e\n\u003cli\u003eEnergy-efficient design with environmentally responsible refrigerant options\u003c\/li\u003e\n\u003cli\u003eFactory inspected and tested for quality assurance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- APPLICATION NOTE --\u003e\n\u003cdiv style=\"margin-top: 30px; padding: 20px; border-left: 5px solid #17384f; background: #f7f7f7;\"\u003e\n\u003ch3 style=\"margin: 0 0 8px; color: #17384f; font-size: 19px;\"\u003eProper Cooling-Water Requirements\u003c\/h3\u003e\n\u003cp style=\"margin: 0;\"\u003eFor dependable operation and protection of the laser system, use only the approved cooling medium specified for the machine. Distilled or deionized water is recommended to reduce mineral buildup, contamination, and restrictions within the cooling circuit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Tommy Industrial","offers":[{"title":"Default Title","offer_id":44093847535694,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1358\/5433\/files\/ChatGPTImageJul29_2026_09_45_00AM.png?v=1785336313","url":"https:\/\/www.tommyindustrial.com\/products\/water-chiller","provider":"Tommy Industrial","version":"1.0","type":"link"}